Advanced Qualification · A-006 Receivers · A-006-004-008
La tension de commande automatique de gain ("AGC") est appliquée :
- Aaux amplificateurs AF et FI
- Baux amplificateurs RF et AF
- Cau détecteur et aux amplificateurs AF
- Daux amplificateurs RF et FI
Correct answer: D — aux amplificateurs RF et FI. Question tirée de la banque officielle d'ISDE.
Why
Automatic Gain Control, or AGC, acts like a volume knob that the radio adjusts itself to keep the sound steady. The full explanation — and one for every question — is in Pro.
Practise this section
Receivers is section A-006 of the Advanced exam: Receivers: superheterodyne design, selectivity, sensitivity, images, AGC and noise.
Drill A-006 — free, no account