If a frequency counter, with a time base accuracy of 10 PPM (parts per million) reads 146 520 000 Hz, what is the most the actual frequency being measured could differ from that reading?

  1. A1465.2 kHz
  2. B1465.2 Hz
  3. C146.52 Hz
  4. D146.52 kHz

Correct answer: B — 1465.2 Hz. From the official ISED question bank, verified word for word.

Why

A time base accuracy of 10 parts per million means the reading can be off by 10 Hz for every million Hz measured. The full explanation — and one for every question — is in Pro.

Practise this section

Measurements is section A-003 of the Advanced exam: Measurements: meters, oscilloscopes, counters, signal generators, and what a reading actually tells you.