SignalPrep
Advanced Qualification · A-003 Measurements · A-003-005-003

How can the frequency response of an oscilloscope be improved?

  1. ABy using a crystal oscillator as the time base and increasing the vertical sweep rate
  2. BBy increasing the vertical sweep rate and the horizontal amplifier frequency response
  3. CBy using triggered sweep and a crystal oscillator for the timebase
  4. DBy increasing the horizontal sweep rate and the vertical amplifier frequency response

Correct answer: D — By increasing the horizontal sweep rate and the vertical amplifier frequency response. From the official ISED question bank, verified word for word.

Why

An oscilloscope shows how a signal changes over time, so its ability to display fast signals depends on two main parts: the vertical amplifier, which handles the signal height, and the horizontal sweep, which moves the trace across the screen. The full explanation — and one for every question — is in Pro.

Practise this section

Measurements is section A-003 of the Advanced exam: Measurements: meters, oscilloscopes, counters, signal generators, and what a reading actually tells you.

Drill A-003 — free, no account

Cette question en français · All A-003 questions