A meter has a full-scale deflection of 40 microamperes and an internal resistance of 96 ohms. You want it to read 0 to 1 mA. The value of the shunt to be used is:

  1. A24 ohms
  2. B16 ohms
  3. C40 ohms
  4. D4 ohms

Correct answer: D — 4 ohms. From the official ISED question bank, verified word for word.

Why

To make the meter read up to 1 mA, most of that current must bypass the delicate coil through a parallel resistor called a shunt. The full explanation — and one for every question — is in Pro.

Practise this section

Measurements is section A-003 of the Advanced exam: Measurements: meters, oscilloscopes, counters, signal generators, and what a reading actually tells you.